nidec industrial loa

industrial solutions

DirectPowerPS
Multi Power Unit

Multi Power Unit
Multi Power Unit 2
Multi Power Unit
Multi Power Unit 2
icon
100 kW

AC Input

400 kW

DC Outputs

Multi Power Unit

Request information
Key Benefits:

Multi addresses the challenge of grid power connection approval in high-density areas by utilizing innovative adaptive technology and efficient energy management. With modular battery integration and support for up to three power units in parallel, Multi connects to the grid with a minimal input power of 100 kW while delivering a high output of 400 kW. Its advanced liquid cooling system, robust safety features, and flexible deployment options ensure reliable and rapid vehicle charging, making it an ideal solution for areas with limited grid power availability.

Key Features:

Adaptive Innovation

Supports up to 3 power units in parallel, each capable of connecting to the AC grid with up to 100 kW for a total of 300kW. Modular battery integration options ranging from 186 kWh to 2.2 MWh.

Low Voltage Connection

Connects to the low voltage grid with a capacity of 100 kW or less, eliminating the need for expensive medium voltage upgrades.

Flexible Deployment

Fast deployment with turnkey solutions including charger management, installation support, and testing, reducing the Total Cost of Ownership (TCO).

High Charging Capacity

Each charging point delivers up to 400 kW, with 2 Charging points of 200kW, enabling rapid charging with minimum grid power

DC-DC Input/Output

The DC Bus technologies allows to have the maximum possible efficiency of the overall system that allows to reduce the Total Cost of Ownership (TCO) for operators.

Efficient Energy Management

Integrated DC architecture allows seamless sharing of power and energy from the grid and batteries. Utilizes excess grid and PV power to charge the battery, enhancing vehicle charging performance.

Battery Integration

Connected to an energy reservoir, storing power during low-demand periods and distributing it during peak charging times. Available battery capacities: 186 kWh, 279 kWh, 372 kWh, 558 kWh, 744 kWh.

Cooling System

Advanced liquid cooling system increases reliability and lifetime of the system

Safety Features

Equipped with overcurrent, overvoltage, surge protection, and overtemperature protections. Includes emergency stop buttons and earthing systems.

Harmonic Filters

EMC filters are integrated to reduce electromagnetic interference. Insulation transformers and reactors are used to ensure clean power conversion and minimize harmonics.

Environmental and Installation Conditions

Operating temperature range -20°C to +50°C. Protection class IP54, suitable for outdoor installation. Maximum operating altitude 2000 m.

Also available:
Downloads

Documentation

ask for more information